Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loudon,
Right arrow Articles by Charnley, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Loudon, , JR
Right arrow Articles by Charnley, J
Journal of Bone and Joint Surgery - British Volume, Vol 62-B, Issue 4, 450-453
Copyright © 1980 by British Editorial Society of Bone and Joint Surgery


Articles

Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem

Loudon JR and J Charnley

A method is described of measuring radiological subsidence of a femoral prosthesis in relation to the femur after total hip arthroplasty. The method depends on measuring the distance from the tip of the femoral prosthesis to a fixed point in the bone. Subsidence after the use of a conventional design of femoral stem is compared with that after the use of a stem with a dorsal flange (Cobra). A significant reduction in the incidence and amount of subsidence was found when using the dorsal flange. There was also a notable absence of transverse fractures involving the cement near the tip of the stem, which occurred in 26 per cent of the cases using a conventional prosthesis.


This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
P. J. Yates, B. J. Burston, E. Whitley, and G. C. Bannister
Collarless polished tapered stem: CLINICAL AND RADIOLOGICAL RESULTS AT A MINIMUM OF TEN YEARS' FOLLOW-UP
J Bone Joint Surg Br, January 1, 2008; 90-B(1): 16 - 22.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
T. Scheerlinck and P.-P. Casteleyn
The design features of cemented femoral hip implants
J Bone Joint Surg Br, November 1, 2006; 88-B(11): 1409 - 1418.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
N. P. Walton, C. Darrah, L. Shepstone, S. T. Donell, and H. Phillips
The Elite Plus total hip arthroplasty: THE NEED FOR RADIOLOGICAL SURVEILLANCE
J Bone Joint Surg Br, April 1, 2005; 87-B(4): 458 - 462.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
M. A. Buttaro, R. Pusso, and F. Piccaluga
Vancomycin-supplemented impacted bone allografts in infected hip arthroplasty: TWO-STAGE REVISION RESULTS
J Bone Joint Surg Br, March 1, 2005; 87-B(3): 314 - 319.
[Abstract] [Full Text] [PDF]



(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General