Logo of The Journal of Bone & Joint Surgery (Br)
Joint Replacement Instrumentation Limited (JRI) Ad
Quick search:        
          Advanced Search
Guest Access | Sign In
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nunn, D
Right arrow Articles by Evans, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nunn, D
Right arrow Articles by Evans, S.
Journal of Bone and Joint Surgery - British Volume, Vol 71-B, Issue 4, 629-631
Copyright © 1989 by British Editorial Society of Bone and Joint Surgery


Articles

The measurement of migration of the acetabular component of hip prostheses

D Nunn, MA Freeman, PF Hill, and SJ Evans

London Hospital Medical College, Bone and Joint Research Unit, England.

Individual components of a total hip replacement are difficult to evaluate and quantify. We have studied the assessment of the acetabular component, and conclude that the measurement of migration allows the comparison of implants, although there is no established link between migration and significant loosening. A method of measurement based on clinical radiographs has been developed, and its limitations estimated. The accuracy of the technique was calculated to be +/- 3 mm.


This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
V. Eswaramoorthy, P. Moonot, Y. Kalairajah, L. C. Biant, and R. E. Field
The Metasul metal-on-metal articulation in primary total hip replacement: CLINICAL AND RADIOLOGICAL RESULTS AT TEN YEARS
J Bone Joint Surg Br, October 1, 2008; 90-B(10): 1278 - 1283.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
A. A. Shetty, R. Slack, A. Tindall, K. D. James, and C. Rand
Results of a hydroxyapatite-coated (Furlong) total hip replacement: A 13- TO 15-YEAR FOLLOW-UP
J Bone Joint Surg Br, August 1, 2005; 87-B(8): 1050 - 1054.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
J. M. Loughead, D. Chesney, J. P. Holland, and A. W. McCaskie
Comparison of offset in Birmingham hip resurfacing and hybrid total hip arthroplasty
J Bone Joint Surg Br, February 1, 2005; 87-B(2): 163 - 166.
[Abstract] [Full Text] [PDF]



(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General