Logo of The Journal of Bone & Joint Surgery (Br)
Joint Replacement Instrumentation Limited (JRI) Ad
Quick search:        
          Advanced Search
Guest Access | Sign In
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boileau, P.
Right arrow Articles by Walch, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boileau, P.
Right arrow Articles by Walch, G.

THE THREE-DIMENSIONAL GEOMETRY OF THE PROXIMAL HUMERUS

IMPLICATIONS FOR SURGICAL TECHNIQUE AND PROSTHETIC DESIGN

P. Boileau, MD

Department of Orthopaedic Surgery, Medical University of Nice-Hôpital de L’Archet, 151 Route de St-Antoine de Ginestière, 06200 Nice, France.

G. Walch, MD

Clinique Emilie de Vialar, 116 Rue Antoine Charrial, Lyon 69003, France.

Correspondence should be sent to Dr P. Boileau.

We have studied the three-dimensional geometry of the proximal humerus on human cadaver specimens using a digitised measuring device linked to a computer. Our findings demonstrated the variable shape of the proximal humerus as well as its variable dimensions. The articular surface, which is part of a sphere varies individually in its orientation as regards inclination and retroversion, and it has variable medial and posterior offsets.

These variations cannot be accommodated by the designs of most contemporary humeral components. Although good clinical results can be achieved with current modular and non-modular components their relatively fixed geometry prevents truly anatomical restoration in many cases.

To try to restore the original three-dimensional geometry of the proximal humerus, we have developed a new type of humeral component which is modular and adaptable to the individual anatomy. Such adaptability allows correct positioning of the prosthetic head in relation to an individual anatomical neck, after removal of the marginal osteophytes. The design of this third-generation prosthesis respects the four geometrical variations which have been demonstrated in the present study. These are inclination, retroversion, medial offset and posterior offset.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
A. E. Kedgley, J. A. DeLude, D. S. Drosdowech, J. A. Johnson, and R. T. Bicknell
Humeral head translation during glenohumeral abduction following computer-assisted shoulder hemiarthroplasty
J Bone Joint Surg Br, September 1, 2008; 90-B(9): 1256 - 1259.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
H. Mullett, O. Levy, D. Raj, T. Even, R. Abraham, and S. A. Copeland
Copeland surface replacement of the shoulder: RESULTS OF AN HYDROXYAPATITE-COATED CEMENTLESS IMPLANT IN PATIENTS OVER 80 YEARS OF AGE
J Bone Joint Surg Br, November 1, 2007; 89-B(11): 1466 - 1469.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
P. Boileau, R. J. Sinnerton, C. Chuinard, and G. Walch
Arthroplasty of the shoulder
J Bone Joint Surg Br, May 1, 2006; 88-B(5): 562 - 575.
[Full Text] [PDF]



(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General