Logo of The Journal of Bone & Joint Surgery (Br)
Joint Replacement Instrumentation Limited (JRI) Ad
Quick search:        
          Advanced Search
Guest Access | Sign In
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McLaughlin, J. R.
Right arrow Articles by Lee, K. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McLaughlin, J. R.
Right arrow Articles by Lee, K. R.

TOTAL HIP ARTHROPLASTY WITH AN UNCEMENTED FEMORAL COMPONENT

EXCELLENT RESULTS AT TEN-YEAR FOLLOW-UP

J. R. McLaughlin, MD, Orthopaedic Surgeon and Director; and K. R. Lee, MS, Head of Research

The Kennedy Center for the Hip and Knee, Suite 100, Theda Clark Medical Plaza, Neenah, Wisconsin 54956-2792, USA.

Correspondence should be sent to Dr J. R. McLaughlin.

We followed 138 patients (145 hips) who had had uncemented total hip arthroplasty using the Taperloc femoral component for a mean of ten years (8 to 12.5). No patient was lost to follow-up; 31 (31 hips) died before the minimum time of eight years for inclusion in the study, and 30 of these still had their femoral component in place. One well-fixed prosthesis had been exchanged at the time of acetabular revision. Of the remaining 114 hips, one femoral component required revision for aseptic loosening and one for sepsis. Three other well-fixed femoral components were removed during acetabular revision.

Complete clinical and radiological follow-up was obtained in the 109 hips which had not had revision. Clinically, 94 (87%) were rated good or excellent, eight (7%) fair and seven (6%) poor. The average Harris hip score increased from 48 before operation to 88 at the time of the last follow-up. Radiologically, 103 hips (94%) had fixation by bone ingrowth, three (3%) showed stable fibrous ingrowth and three (3%) were unstable. Osteolysis of the femoral cortex was seen in seven hips (6%), with major lysis in only one.

At a mean follow-up of ten years, the results of the Taperloc femoral component are comparable with those of modern techniques of cementing in primary total hip arthroplasty.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
G. Hallan, S. A. Lie, O. Furnes, L. B. Engesaeter, S. E. Vollset, and L. I. Havelin
Medium- and long-term performance of 11 516 uncemented primary femoral stems from the Norwegian arthroplasty register
J Bone Joint Surg Br, December 1, 2007; 89-B(12): 1574 - 1580.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
J. R. McLaughlin and K. R. Lee
The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years
J Bone Joint Surg Br, October 1, 2006; 88-B(10): 1286 - 1292.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
Y.-H. Kim
Long-term results of the cementless porous-coated anatomic total hip prosthesis
J Bone Joint Surg Br, May 1, 2005; 87-B(5): 623 - 627.
[Abstract] [Full Text] [PDF]



(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General