Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 84-B, Issue 3, 447-451.
doi: 10.1302/0301-620X.84B3.11344  
Copyright © 2002 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eggli, S.
Right arrow Articles by Ganz, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eggli, S.
Right arrow Articles by Ganz, R.

Comparison of polyethylene wear with femoral heads of 22 mm and 32 mm

A PROSPECTIVE, RANDOMISED STUDY

S. Eggli, MD1; S. z’Brun, MD1; C. Gerber, MD2; and R. Ganz, MD1

1 Department of Orthopaedic Surgery, University of Berne, Inselspital, CH-3010 Berne, Switzerland.
2 Department of Orthopaedic Surgery, University of Zürich, Balgrist, CH-8008 Zürich, Switzerland.

Correspondence should be sent to Dr S. Eggli.

In this prospective, randomised study, we have compared the wear rate of cemented, acetabular polyethylene cups articulating with either a 22 mm or a 32 mm cobalt-chromium head. We evaluated 89 patients who had a total of 484 radiographs. The mean follow-up period was 71.4 months (SD 29.1). All the radiographs were digitised and electronically measured.

The linear wear rate was significantly higher during the first two years and decreased after this period to a constant value. We suggest that this is partly due to a ‘run-in’ process caused by irregularities between surfaces of the cup and head and an initial plastic deformation of the polyethylene. The mean volumetric wear was 120.3 mm3/year for the 32 mm head, which was significantly higher than the 41.5 mm3/year for the 22 mm heads. The mean linear wear rate was not significantly different. We were, however, unable to find radiological signs of osteolysis in the patients who had higher wear rates.






(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved