Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 85-B, Issue 3, 376-379.
doi: 10.1302/0301-620X.85B3.13817  
Copyright © 2003 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wroblewski, B. M.
Right arrow Articles by Fleming, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wroblewski, B. M.
Right arrow Articles by Fleming, P. A.

Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head

B. M. Wroblewski, FRCS, Professor of Orthopaedic Biomechanics, Consultant Orthopaedic Surgeon; P. D. Siney, BA, Senior Research Fellow; and P. A. Fleming, Research Assistant

The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, Wigan WN6 9EP, UK.

Correspondence should be sent to Miss P. A. Fleming.

We have prospectively studied the wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a zirconia femoral head of 22.225 mm diameter on a cemented, triple-tapered, collarless, polished stem, the C Stem.

The 71 patients who underwent total hip arthroplasty had a mean follow-up of six years (3 to 8). No patient died or was lost to follow-up. The clinical results were excellent with 96% of patients satisfied. There were no revisions. Two cups were considered to be loose radiologically. One was avulsed from the cement in a skiing accident, with a periprosthetic fracture of the femur, but has remained stable for more than seven years. One femur shows radiological appearances which are compatible with a healing infection. One femoral component is at risk of loosening. The mean rate of penetration of the cup was 0.22 mm/year (0.06 to 0.55).

Our results appear to be within the guidelines set by the National Institute of Clinical Excellence. We have discontinued the use of Hylamer despite excellent clinical results and no revisions to date because the high initial rates of penetration did not settle to the expected low levels within the anticipated time.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
T. von Schewelov, L. Sanzen, I. Onsten, A. Carlsson, and J. Besjakov
Total hip replacement with a zirconium oxide ceramic femoral head: A RANDOMISED ROENTGEN STEREOPHOTOGRAMMETRIC STUDY
J Bone Joint Surg Br, December 1, 2005; 87-B(12): 1631 - 1635.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
M. Sundberg, J. Besjakov, T. von Schewelow, and A. Carlsson
Movement patterns of the C-stem femoral component: AN RSA STUDY OF 33 PRIMARY TOTAL HIP ARTHROPLASTIES FOLLOWED FOR TWO YEARS