Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 87-B, Issue 12, 1631-1635.
doi: 10.1302/0301-620X.87B12.16873  
Copyright © 2005 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Further opinion
Right arrow FrenchSpanishGermanItalianRomanianPolishRussianCzech
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by von Schewelov, T.
Right arrow Articles by Besjakov, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by von Schewelov, T.
Right arrow Articles by Besjakov, J.

Total hip replacement with a zirconium oxide ceramic femoral head

A RANDOMISED ROENTGEN STEREOPHOTOGRAMMETRIC STUDY

T. von Schewelov, MD, Orthopaedic Surgeon1; L. Sanzén, MD, PhD, Orthopaedic Surgeon1; I. Önsten, MD, PhD, Orthopaedic Surgeon1; Å. Carlsson, MD, PhD, Orthopaedic Surgeon1; and J. Besjakov, MD, PhD, Radiologist2

1 Department of Orthopaedics
2 Department of Radiology Malmö University Hospital, 205 02 Malmö, Sweden.

Correspondence should be sent to Dr T. von Schewelov; e-mail: Thord.von_Schewelov{at}orto.mas.lu.se

We investigated the wear characteristics and clinical performance of four different total hip joint articulations in 114 patients. Wear and migration was measured by roentgenstereophotogrammetric analysis at five years or at the last follow-up. The mean annual wear was 0.11 mm for a stainless steel/Enduron articulation, 0.34 mm for stainless steel/Hylamer cup, 0.17 mm for zirconium oxide ceramic/Enduron and 0.40 mm for zirconium oxide ceramic/Hylamer. The difference between the groups was significant (p < 0.008) except for stainless steel/Hylamer vs zirconium oxide ceramic/Hylamer (p = 0.26).

At present, 12 patients have undergone a revision procedure, four at five years and eight thereafter. No patient who received a stainless steel/Enduron articulation at their primary replacement required revision.

Conflicting results have been reported about the performance of the zirconium oxide ceramic femoral head, but our findings suggest that it should not be used with a polymethylmethacrylate acetabular component. Hylamer has already been withdrawn from the market.






(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved