Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 87-B, Issue 5, 623-627.
doi: 10.1302/0301-620X.87B5.15554  
Copyright © 2005 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow FrenchSpanishGermanItalianRomanianPolishRussianCzech
Right arrow Submit a response
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, Y.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, Y.-H.

Long-term results of the cementless porous-coated anatomic total hip prosthesis

Y.-H. Kim, MD, Professor and Director

The Joint Replacement Centre of Korea, Ewha Womans University Dong Dae Mun Hospital, 70 ChongRo 6-Ga, ChongRo-Gu, Seoul 110-783, Korea.

Correspondence should be sent to Professor Y.-H. Kim; e-mail: younghookim{at}netsgo.com

Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20).

The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
M. Ihle, S. Mai, D. Pfluger, and W. Siebert
The results of the titanium-coated RM acetabular component at 20 years: A LONG-TERM FOLLOW-UP OF AN UNCEMENTED PRIMARY TOTAL HIP REPLACEMENT
J Bone Joint Surg Br, October 1, 2008; 90-B(10): 1284 - 1290.
[Abstract] [Full Text] [PDF]

eLetters:

Read all eLetters

Complications of cementless stems
Manoj Todkar
J Bone Joint Surg Br Online, 12 May 2005 [Full text]
Response to Mr Todkar
Young-Hoo Kim
J Bone Joint Surg Br Online, 13 Jun 2005 [Full text]


(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General