Logo of The Journal of Bone & Joint Surgery (Br)
Quick search:        
          Advanced Search
Guest Access | Sign In
Journal of Bone and Joint Surgery - British Volume, Vol 90-B, Issue 8, 1084-1089.
doi: 10.1302/0301-620X.90B8.20240  
Copyright © 2008 by British Editorial Society of Bone and Joint Surgery
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow FrenchSpanishGermanItalianRomanianPolishRussianCzechGreek
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guo, W.
Right arrow Articles by Yang, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guo, W.
Right arrow Articles by Yang, Y.

Endoprosthetic replacement for primary tumours around the knee

EXPERIENCE FROM PEKING UNIVERSITY

W. Guo, MD, PhD, Professor1; T. Ji, MD, Orthopaedic Surgeon1; R. Yang, MD, Associate Professor1; X. Tang, MD, Orthopaedic Surgeon1; and Y. Yang, MD, Orthopaedic Surgeon1

1 Musculoskeletal Tumor Centre, People’s Hospital, Peking University, 11# Xizhimen Nan Road, Xicheng District, Beijing, 100044, China.

Correspondence should be sent to Professor W. Guo; e-mail: sarcomasurgeon_cn{at}yahoo.com.cn

In developing countries locally-made low-cost prostheses are mainly used in limb-salvage surgery to alleviate the economic burden.

We retrospectively collected data on 104 patients treated by limb-salvage surgery between July 1997 and July 2005. We used a locally-designed and fabricated stainless-steel endoprosthesis in each case. Oncological and functional outcomes were evaluated at a mean follow-up of 47 months (12 to 118).

A total of 73 patients (70.2%) were free from disease, nine (8.7%) were alive with disease, 19 (18.2%) had died from their disease and three (2.9%) from unrelated causes. According to the Musculoskeletal Tumor Society scoring system, the mean functional score was 76.3% (SD 17.8). The five-year survival for the implant was 70.5%. There were nine cases (8.7%) of infection, seven early and two late, seven (6.7%) of breakage of the prosthesis, three (2.9%) of aseptic loosening and two (1.9%) of failure of the polyethylene bushing. Multivariate analysis showed that a proximal tibial prosthesis and a resection length of 14 cm or more were significant negative prognostic factors.

Our survival rates and Musculoskeletal Tumor Society functional scores are similar to those reported in the literature. Although longer follow-up is needed to confirm our results, we believe that a low-cost custom-made endoprosthesis is a cost-effective and reliable reconstructive option for limb salvage in developing countries.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
M. D. Sewell, B. G. I. Spiegelberg, S. A. Hanna, W. J. S. Aston, W. Bartlett, G. W. Blunn, L. A. David, S. R. Cannon, and T. W. R. Briggs
Total femoral endoprosthetic replacement following excision of bone tumours
J Bone Joint Surg Br, November 1, 2009; 91-B(11): 1513 - 1520.
[Abstract] [Full Text] [PDF]



(c) British Editorial Society of Bone and Joint Surgery All Rights Reserved
Registered charity no: 209299     Print ISSN: 0301-620X
Hip, Knee, Trauma, Upper limb, Foot & Ankle, Paediatrics, Oncology, Spine, Arthroplasty, General